Seismic Analysis of Reticulated Shell Structure Based on Sensor Network for Smart Transportation Seismic Isolation Bearings
Earthquakes are one of the most frequent and inevitable natural disasters that occur on Earth. The most important seismic isolation device used in the isolation technology is the isolation bearing, but the limited structure of the isolation bearing is not suitable for the seismic isolation and shock...
Gespeichert in:
Veröffentlicht in: | Journal of advanced transportation 2022-04, Vol.2022, p.1-13 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Earthquakes are one of the most frequent and inevitable natural disasters that occur on Earth. The most important seismic isolation device used in the isolation technology is the isolation bearing, but the limited structure of the isolation bearing is not suitable for the seismic isolation and shock absorption of smart transportation buildings. Therefore, it is very important to improve the new generation of seismic isolation structures with good seismic isolation effect, stable performance, and economical performance. It is very important to study the structural composition of the isolation bearing and the rigidity of the isolation structure. Isolation bearings are designed to resist and absorb the energy of seismic shocks by installing substructures in the structure. Active control involves installing sensors on the structure and its foundation to determine how the structure responds to seismic action. In this paper, based on the intelligent transportation of the sensor network, the reticulated shell structure of the isolation bearing is analyzed. By introducing the architecture and network layout of the sensor network, it is beneficial to obtain more accurate seismic data in complex and difficult terrain. This paper analyzes the technical principle of seismic isolation technology, which can effectively avoid the upward transmission of ground vibration by increasing the flexibility and proper damping of the system. From the experimental data of the seismic response of the ground-isolated structure to the near-field pulsation and far-field vibration, the total energy of the ground-isolated structure under the near-field pulsed ground motion is the largest. The seismic isolation effect of the reticulated shell structure of the seismic isolation bearing prevents more than 80% of the seismic energy from being transmitted to the superstructure. |
---|---|
ISSN: | 0197-6729 2042-3195 |
DOI: | 10.1155/2022/5985542 |