Comparative Pharmacokinetics, Bioequivalence and Safety Study of Two Recombinant Human Chorionic Gonadotropin Injections in Healthy Chinese Subjects
To evaluate the pharmacokinetics (PK), bioequivalence and safety profile of the recombinant human chorionic gonadotropin (r-hCG) injection formulation LZM003 (test drug) comparing with that of Ovidrel (reference drug) in healthy Chinese subjects. This is a randomized, single-blind, single-dose, two-...
Gespeichert in:
Veröffentlicht in: | Drug design, development and therapy development and therapy, 2020-01, Vol.14, p.435-444 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To evaluate the pharmacokinetics (PK), bioequivalence and safety profile of the recombinant human chorionic gonadotropin (r-hCG) injection formulation LZM003 (test drug) comparing with that of Ovidrel
(reference drug) in healthy Chinese subjects.
This is a randomized, single-blind, single-dose, two-arm and two-period crossover Phase I study. Subjects were randomized evenly to a single dose of LZM003 or reference drug injected subcutaneously, with a 10-day or longer between-treatment washout period. PK parameters, anti-drug antibodies (ADAs), and adverse events (AEs) were assessed. The primary PK endpoints were area under the curve (AUC) of the concentration-time curve from zero to last quantifiable concentration (AUC
), AUC from zero to infinity (AUC
), and peak concentration (C
). Bioequivalence was determined by assessing whether the 90% confidence intervals (CIs) for the geometric mean ratio (GMR) of LZM003 to reference drug fell within predefined margins of 80% -125%.
Forty-eight subjects (24 males and 24 females) were enrolled and one subject withdrew for personal reasons. Mean values of primary PK parameters were similar (p > 0.05) between LZM003 and the reference drug. The 90% CIs for primary PK endpoints' GMR of LZM003 to reference drug ranged between 0.9144 and 1.1845, which were within bioequivalence margins of 80-125%. Incidence of AEs was similar (p > 0.05) between the two groups. Neither LZM003 nor reference drug produced anti-drug antibody (ADA) in healthy subjects.
LZM003 and reference drug were bioequivalent. The PK and safety assessments were similar (p > 0.05) between the two formulations in healthy Chinese subjects.
ChiCTR-IIR-16010158 (http://www.chictr.org.cn).
December 15, 2016. |
---|---|