Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis : an experimental study in pigs

Diagnosis of the etiologic agent of endoprosthesis infections is essential to enable treatment, since these infections constitute important complications of endovascular procedures. Sonication of explanted tissue and materials is a technique that can be used to facilitate detection of biofilm-produc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Jornal vascular brasileiro 2021-01, Vol.20, p.e20200157-e20200157
Hauptverfasser: Dutra, Clandio de Freitas, Pereira, Adamastor Humberto, Wollheim, Claudia, Pongiluppi, Rodrigo, Fellini, Roberto, Gomes, Sérgio Ventura, Nonemacher, Henrique
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Diagnosis of the etiologic agent of endoprosthesis infections is essential to enable treatment, since these infections constitute important complications of endovascular procedures. Sonication of explanted tissue and materials is a technique that can be used to facilitate detection of biofilm-producing bacteria. To evaluate infection of pigs' aortas after implantation of nitinol stents coated with polytetrafluoroethylene (ePTFE) or Dacron, previously infected with biofilm-producing . Intimal thickening and the inflammatory response in the aortic wall were also evaluated. 11 ePTFE-coated nitinol stents and 10 Dacron stents infected with strains were implanted in the infrarenal aorta of 21 8-week-old pigs. After 2 weeks, the aorta containing the stents was removed. A vortex mixer and ultrasound were used to homogenize the samples and remove the biofilm. Subsequently, the number of colony-forming units was counted. There were no significant differences between the two groups in terms of the number of colony-forming units or of inflammation in the arterial wall. With the exception of one specimen from the Dacron group, all aortic stent cultures were positive for . There were no significant differences in the inflammatory response or infection rate between ePTFE and Dacron-coated stents actively infected with biofilm-producing . Intimal thickening and the inflammatory response to infection of endoprostheses were similar. These results suggest that the two most widely used stent lining materials have a similar infection rate.
ISSN:1677-5449
1677-7301
1677-7301