Usefulness of Combining NT-proBNP Level and Right Atrial Diameter for Simple and Early Noninvasive Detection of Pulmonary Hypertension Among Adult Patients with Atrial Septal Defect

Atrial septal defect developed pulmonary hypertension (ASD-PH) at first diagnosis due to late presentation are common in Indonesia. Transthoracic echocardiogram (TTE) is a common tool to detect ASD-PH, before proceeding to invasive procedure. The NT-proBNP measurement to screen ASD-PH is not yet con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta medica Indonesiana 2022-10, Vol.54 (4), p.556-566
Hauptverfasser: Hartopo, Anggoro Budi, Anggrahini, Dyah Wulan, Satwiko, Muhammad Gahan, Damarkusuma, Arditya, Pritazahra, Armalya, Hadwiono, Muhammad Reyhan, Dewanto, Vera Christina, Di Somma, Salvatore, Emoto, Noriaki, Dinarti, Lucia Kris
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Atrial septal defect developed pulmonary hypertension (ASD-PH) at first diagnosis due to late presentation are common in Indonesia. Transthoracic echocardiogram (TTE) is a common tool to detect ASD-PH, before proceeding to invasive procedure. The NT-proBNP measurement to screen ASD-PH is not yet considered the standard approach, especially in limited resource conditions. The objective of this study is to assess the value of NT-proBNP, along with simple TTE parameter, to screen PH among adults with ASD. This was a cross-sectional study. The subjects were adult ASD-PH patients from the COHARD-PH  registry (n=357). Right heart catheterization (RHC) was performed to diagnose PH. Blood sample was withdrawn during RHC for NT-proBNP measurement. The TTE was performed as standard procedure and its regular parameters were assessed, along with NT-proBNP, to detect PH. Two parameters significantly predicted PH, namely NT-proBNP and right atrial (RA) diameter. The cut-off of NT-proBNP to detect PH was ≥140 pg/mL. The cut-off of RA diameter to detect PH was ≥46.0 mm. The combined values of NT-proBNP level ≥140 pg/mL and RA diameter ≥46.0 mm yielded 46.6% sensitivity, 91.8% specificity, 54.3% accuracy, 96.5% positive predictive value and 26.2% negative predictive value to detect PH, which were better than single value. NT-proBNP level ≥140 pg/mL represented PH in adult ASD patients. The NT-proBNP level ≥140 pg/mL and RA diameter ≥46.0 mm had a pre-test probability measures to triage patients needing more invasive procedure and also to determine when and if to start the PH-specific treatment.
ISSN:0125-9326