Experimental investigation on split type window Air conditioner using HFC and HC mixture as ecofriendly refrigerant alternate to HCFC-22

This paper reports on an experimental study evaluating a window air conditioner's performance when R152a/R290/R600/R600a refrigerant mixture (by various mass percentages) is used as a possible alternative to R-22. Alternative refrigerants are local, cheap, and environmentally friendly. Unmodifi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Karthik, Ganapathi, Parthiban, A., Sasikumar, C., Krishnan, B. Radha
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper reports on an experimental study evaluating a window air conditioner's performance when R152a/R290/R600/R600a refrigerant mixture (by various mass percentages) is used as a possible alternative to R-22. Alternative refrigerants are local, cheap, and environmentally friendly. Unmodified R-22 window AC was charged with R152a/R290/R600/R600a. During the experiment, parameters such as coefficient of performance, refrigeration effect, pressure ratio, compressor discharge temperature, refrigerant mass flow rate, and compressor power are analyzed. The present work shows that R152a-15%/R290-15%/R600-35%/R600a-35% is the best-performing alternative refrigerant. Proposed blends and R22's performance were compared.
ISSN:2267-1242
2555-0403
2267-1242
DOI:10.1051/e3sconf/202339906004