The Impact of Coil Winding Angle on the Force of DC Solenoid Electromagnetic Actuator

This paper presents the research on the influence of coil parameter on the force of DC electromagnetic actuator. The coil parameter discussed in the paper is the angle between the windings. The research method is based on analyzing the magnetic path of DC electromagnetic actuator and on comparison o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advances in electrical and electronic engineering 2019-09, Vol.17 (3), p.244-250
Hauptverfasser: Plavec, Eduard, Ladisic, Ivan, Vidovic, Mladen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents the research on the influence of coil parameter on the force of DC electromagnetic actuator. The coil parameter discussed in the paper is the angle between the windings. The research method is based on analyzing the magnetic path of DC electromagnetic actuator and on comparison of analytically obtained results with the numerical simulation results. Transient numerical simulation of DC electromagnetic actuator has been performed on the 2D axial-symmetric model using the Finite Element Method (FEM). The main contribution is the coil winding angle impact on the force of DC electromagnetic actuator. The results showed that, by reducing the coil winding angle, it is possible to increase the electromagnetic force, reduce the coil dimensions, and thus the dimensions of electromagnetic actuator.
ISSN:1336-1376
1804-3119
DOI:10.15598/aeee.v17i3.3338