Distribution of the temperature in the coaxial tube heat exchanger with spherical end

A solution is presented for flow inside a heat exchanger. An analytical approach is developed and validated with a numerical simulation using ANSYS CFX code module taking account different boundary condition in the inlet. The temperature distribution of the laminar flow is presented, which is relate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Case studies in thermal engineering 2017-09, Vol.10 (C), p.621-627
Hauptverfasser: Imen, Dhahri, Ammar, Lotfi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A solution is presented for flow inside a heat exchanger. An analytical approach is developed and validated with a numerical simulation using ANSYS CFX code module taking account different boundary condition in the inlet. The temperature distribution of the laminar flow is presented, which is related to Reynolds number and the hydraulic diameter of the heat exchanger.
ISSN:2214-157X