Mathematical modeling of non-steady heat exchange process in cryogenic coil-wound heat exchangers
The paper discusses a dynamic model of coil-wound heat exchanger and its implementation in the MathWorks Simulink TM computer simulation system. As a simulation object was chosen a coil-wound heat exchanger with wire-finned tubes of a commercial low-capacity air separation unit. The methods for obta...
Gespeichert in:
Veröffentlicht in: | MATEC web of conferences 2020, Vol.324, p.1009 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The paper discusses a dynamic model of coil-wound heat exchanger and its implementation in the MathWorks Simulink
TM
computer simulation system. As a simulation object was chosen a coil-wound heat exchanger with wire-finned tubes of a commercial low-capacity air separation unit. The methods for obtaining experimental data has been described, the non-steady heat exchange process has been simulated, and the obtained results have been analyzed. |
---|---|
ISSN: | 2261-236X 2274-7214 2261-236X |
DOI: | 10.1051/matecconf/202032401009 |