Validity and Reliability of the Urdu Version of the McLean Screening Instrument for Borderline Personality Disorder
Introduction: Although the translation and the validation of the McLean Screening Instrument for Borderline Personality Disorder (MSI-BPD) are performed in various languages and samples, no study has established the validity and reliability of the Urdu version of MSI-BPD in individuals with cardiac...
Gespeichert in:
Veröffentlicht in: | Frontiers in psychology 2021-08, Vol.12, p.533526-533526 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction:
Although the translation and the validation of the McLean Screening Instrument for Borderline Personality Disorder (MSI-BPD) are performed in various languages and samples, no study has established the validity and reliability of the Urdu version of MSI-BPD in individuals with cardiac problems.
Materials and Methods:
The Urdu version of the MSI-BPD was prepared through the standard back-translation method. The translation and adaption were completed in four steps: forward translation, adaption and translation, back translation and committee approach, and cross-language validation. The sample, selected through the purposive sampling method, comprised of 150 adults with cardiac problems (men = 75 and women = 75), with an age range of 23–78 years (
M
= 55,
SD
= 10.6). The Cronbach alpha reliability and factorial validity of the MSI-BPD were assessed through confirmatory factor analysis (CFA) and Pearson correlation analyses. Internal consistency and test–retest reliability (at 2 weeks' interval) were used to evaluate the reliability. Statistical analyses were performed, using SPSS (version 22) and Structural Equation Modeling (SEM) software.
Results:
Preliminary analysis revealed that the overall instrument had good internal consistency (Urdu MSI-BPD α = 0.79; English MSI-BPD α = 0.77) as well as test–retest correlation coefficients for 15 days (
r
= 0.94).
Conclusions:
Findings suggested that the MSI-BPD, with important limitations, can be used as an effective preliminary screening tool to measure BPD in Urdu-speaking adults with cardiac problems. Further validations should be conducted to make the translated version of the MSI-BPD an appropriate tool to screen BPD in hospitals and mental health care settings. |
---|---|
ISSN: | 1664-1078 1664-1078 |
DOI: | 10.3389/fpsyg.2021.533526 |