The reality of advanced airway management during out of hospital cardiac arrest; why did paramedics deviate from their allocated airway management strategy during the AIRWAYS-2 randomised trial?

AIRWAYS-2 was a large multi-centre cluster randomised controlled trial investigating the effect on functional outcome of a supraglottic airway device (i-gel) versus tracheal intubation (TI) as the initial advanced airway during out-of-hospital cardiac arrest. We aimed to understand why paramedics de...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Resuscitation plus 2023-03, Vol.13, p.100365-100365, Article 100365
Hauptverfasser: Kirby, K., Lazaroo, M., Green, J., Hall, H., Pilbery, R., Whitley, G.A., Voss, S., Benger, J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:AIRWAYS-2 was a large multi-centre cluster randomised controlled trial investigating the effect on functional outcome of a supraglottic airway device (i-gel) versus tracheal intubation (TI) as the initial advanced airway during out-of-hospital cardiac arrest. We aimed to understand why paramedics deviated from their allocated airway management algorithm during AIRWAYS-2. This study employed a pragmatic sequential explanatory design utilising retrospective study data collected during the AIRWAYS-2 trial. Airway algorithm deviation data were analysed to categorise and quantify the reasons why paramedics did not follow their allocated strategy of airway management during AIRWAYS-2. Recorded free text entries provided additional context to the paramedic decision-making related to each category identified. In 680 (11.7%) of 5800 patients the study paramedic did not follow their allocated airway management algorithm. There was a higher percentage of deviations in the TI group (399/2707; 14.7%) compared to the i-gel group (281/3088; 9.1%). The predominant reason for a paramedic not following their allocated airway management strategy was airway obstruction, occurring more commonly in the i-gel group (109/281; 38.7%) versus (50/399; 12.5%) in the TI group. There was a higher proportion of deviations from the allocated airway management algorithm in the TI group (399; 14.7%) compared to the i-gel group (281; 9.1%). The most frequent reason for deviating from the allocated airway management algorithm in AIRWAYS-2 was obstruction of the patient’s airway by fluid. This occurred in both groups of the AIRWAYS-2 trial, but was more frequent in the i-gel group.
ISSN:2666-5204
2666-5204
DOI:10.1016/j.resplu.2023.100365