Electrochemical Detection of Ammonia in Water Using NiCu Carbonate Hydroxide-Modified Carbon Cloth Electrodes: A Simple Sensing Method

Excessive ammonia nitrogen can potentially compromise the safety of drinking water. Therefore, developing a rapid and simple detection method for ammonia nitrogen in drinking water is of great importance. Nickel-copper hydroxides exhibit strong catalytic capabilities and are widely applied in ammoni...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors (Basel, Switzerland) Switzerland), 2024-07, Vol.24 (15), p.4824
Hauptverfasser: Zhou, Guangfeng, Wang, Guanda, Zhao, Xing, He, Dong, Zhao, Chun, Suo, Hui
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Excessive ammonia nitrogen can potentially compromise the safety of drinking water. Therefore, developing a rapid and simple detection method for ammonia nitrogen in drinking water is of great importance. Nickel-copper hydroxides exhibit strong catalytic capabilities and are widely applied in ammonia nitrogen oxidation. In this study, a self-supported electrode made of nickel-copper carbonate hydroxide was synthesized on a carbon cloth collector via a straightforward one-step hydrothermal method for rapid ammonia nitrogen detection in water. It exhibits sensitivities of 3.9 μA μM cm and 3.13 μA μM cm within linear ranges of 1 μM to 100 μM and 100 μM to 400 μM, respectively, using a simple and rapid i-t method. The detection limit is as low as 0.62 μM, highlighting its excellent anti-interference properties against various anions and cations. The methodology's simplicity and effectiveness suggest broad applicability in water quality monitoring and environmental protection, particularly due to its significant cost-effectiveness.
ISSN:1424-8220
1424-8220
DOI:10.3390/s24154824