Performance of liver stiffness measurements obtained with FibroScan is affected by glucose metabolism in patients with nonalcoholic fatty liver disease

The performance of liver stiffness measurements (LSMs) obtained using FibroScan can be affected by several factors, and cut-off values are different for fibrosis caused by various aetiologies. The study aims to evaluate the diagnostic accuracy of LSM in nonalcoholic fatty liver disease (NAFLD) patie...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lipids in health and disease 2021-03, Vol.20 (1), p.27-27, Article 27
Hauptverfasser: Yang, Xinyu, Chang, Xinxia, Wu, Shengdi, Sun, Xiaoyang, Zhu, Xiaopeng, Wang, Liu, Xu, Yushan, Yao, Xiuzhong, Rao, Shengxiang, Hu, Xiqi, Xia, Mingfeng, Bian, Hua, Yan, Hongmei, Gao, Xin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The performance of liver stiffness measurements (LSMs) obtained using FibroScan can be affected by several factors, and cut-off values are different for fibrosis caused by various aetiologies. The study aims to evaluate the diagnostic accuracy of LSM in nonalcoholic fatty liver disease (NAFLD) patients with abnormal glucose metabolism and investigate whether the LSM value would be affected by metabolic indicators. The study involved 91 NAFLD patients with abnormal glucose metabolism who underwent liver biopsy. The diagnostic accuracy of LSM value was evaluated by the receiver operator characteristic (ROC) curves, with the biopsy results taken as the gold standard. Multivariate linear regression and subgroup analysis were performed to determine the correlated indicators. The areas under the ROC curves (AUROCs) of LSM values for detecting fibrosis stage ≥1, 2, 3 and 4 were 0.793 (95% confidence interval [CI]: 0.695-0.871), 0.764 (95% CI: 0.663-0.846), 0.837 (95% CI: 0.744-0.906) and 0.902 (95% CI: 0.822-0.955), with cut-off values of 6.3, 7.6, 8.3 and 13.8 kPa, respectively. Multivariate linear regression demonstrated that haemoglobin A1c (HbA1c, β = 0.205, P = 0.026) and alanine aminotransferase (ALT, β = 0.192, P = 0.047) were independently associated with the LSM value after adjustment for fibrosis stage, ballooning and inflammation grade from liver biopsy. Subgroup analysis demonstrated that LSM values were slightly higher in patients with HbA1c ≥7% than in those with HbA1c
ISSN:1476-511X
1476-511X
DOI:10.1186/s12944-021-01453-5