Fluorescent aptasensor for detection of live foodborne pathogens based on multicolor perovskite-quantum-dot-encoded DNA probes and dual-stirring-bar-assisted signal amplification

In this study, a fluorescent (FL) aptasensor was developed for on-site detection of live Salmonella typhimurium (S.T.) and Vibrio parahaemolyticus (V.P.). Complementary DNA (cDNA) of aptamer (Apt)-functionalized multicolor polyhedral oligomeric silsesquioxane-perovskite quantum dots (cDNA-POSS-PQDs)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical analysis 2022-12, Vol.12 (6), p.913-922
Hauptverfasser: Liu, Liu, Hong, Juncheng, Wang, Wenhai, Xiao, Shu, Xie, Hongzhen, Wang, Qiqin, Gan, Ning
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, a fluorescent (FL) aptasensor was developed for on-site detection of live Salmonella typhimurium (S.T.) and Vibrio parahaemolyticus (V.P.). Complementary DNA (cDNA) of aptamer (Apt)-functionalized multicolor polyhedral oligomeric silsesquioxane-perovskite quantum dots (cDNA-POSS-PQDs) were used as encoded probes and combined with dual-stirring-bar-assisted signal amplification for pathogen quantification. In this system, bar 1 was labeled with the S.T. and V.P. Apts, and then bar 2 was functionalized with cDNA-POSS-PQDs. When S.T. and V.P. were introduced, pathogen-Apt complexes would form and be released into the supernatant from bar 1. Under agitation, the two complexes reached bar 2 and subsequently reacted with cDNA-POSS-PQDs, which were immobilized on MXene. Then, the encoded probes would be detached from bar 2 to generate FL signals in the supernatant. Notably, the pathogens can resume their free state and initiate next cycle. They swim between the two bars, and the FL signals can be gradually enhanced to maximum after several cycles. The FL signals from released encoded probes can be used to detect the analytes. In particular, live pathogens can be distinguished from dead ones by using an assay. The detection limits and linear range for S.T. and V.P. were 30 and 10 CFU/mL and 102–106 CFU/mL, respectively. Therefore, this assay has broad application potential for simultaneous on-site detection of various live pathogenic bacteria in water. [Display omitted] •A FL aptasensor was designed for simultaneous detection of live V.P. and S.T.•Multicolor PQD-encoded DNA probes were proposed for detection.•Dual-stirring-bar-assisted target recycling was used to improve sensitivity.•Superior specificity, anti-interference ability, and sensitivity were achieved.
ISSN:2095-1779
2214-0883
DOI:10.1016/j.jpha.2022.07.001