Optimization of collimator angles in dual-arc volumetric modulated arc therapy planning for whole-brain radiotherapy with hippocampus and inner ear sparing

To optimize the collimator angles in dual-arc volumetric modulated arc therapy (VMAT) plans for whole-brain radiotherapy with hippocampus and inner ear sparing (HIS-WBRT). Two sets of dual-arc VMAT plans were generated for 13 small-cell lung cancer patients: (1) The collimator angles of arcs 1 and 2...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2021-09, Vol.11 (1), p.19035-8, Article 19035
Hauptverfasser: Sun, Wuji, Chen, Kunzhi, Li, Yu, Xia, Wenming, Dong, Lihua, Shi, Yinghua, Ge, Chao, Yang, Xu, Wang, Libo, Wang, Huidong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To optimize the collimator angles in dual-arc volumetric modulated arc therapy (VMAT) plans for whole-brain radiotherapy with hippocampus and inner ear sparing (HIS-WBRT). Two sets of dual-arc VMAT plans were generated for 13 small-cell lung cancer patients: (1) The collimator angles of arcs 1 and 2 ( θ 1 / θ 2 ) were 350°/10°, 350°/30°, 350°/45°, 350°/60°, and 350°/80°, i.e., the intersection angle of θ 1 and θ 2 (Δ θ ) increased. (2) θ 1 / θ 2 were 280°/10°, 300°/30°, 315°/45°, 330°/60°, and 350°/80°, i.e., Δ θ  = 90°. The conformity index ( CI ), homogeneity index ( HI ), monitor units (MUs), and dosimetric parameters of organs-at-risk were analyzed. Quality assurance for Δ θ  = 90° plans was performed. With Δ θ increasing towards 90°, a significant improvement was observed for most parameters. In 350°/80° plans compared with 350°/10° ones, CI and HI were improved by 1.1% and 25.2%, respectively; MUs were reduced by 16.2%; minimum, maximum, and mean doses ( D 100% , D max , and D mean , respectively) to the hippocampus were reduced by 5.5%, 6.3%, and 5.4%, respectively; D mean to the inner ear and eye were reduced by 0.7% and 5.1%, respectively. With Δ θ kept at 90°, the plan quality was not significantly affected by θ 1 / θ 2 combinations. The gamma-index passing rates in 280°/10° and 350°/80° plans were relatively lower compared with the other Δ θ  = 90° plans. Δ θ showed a significant effect on dual-arc VMAT plans for HIS-WBRT. With Δ θ approaching 90°, the plan quality exhibited a nearly continuous improvement, whereas with Δ θ  = 90°, the effect of θ 1 / θ 2 combination was insignificant.
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-021-98530-7