Abstract Objective To demonstrate the technique and clinical safety of primary entry of an optically guided entry approach in laparoscopic surgery. Materials The clinical data from a personal series of 821 consecutive cases of laparoscopic surgery were used. Methods The technique of an optically gui...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gynecology and minimally invasive therapy 2013-02, Vol.2 (1), p.30-33
1. Verfasser: Wong, Wu Shun Felix
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Objective To demonstrate the technique and clinical safety of primary entry of an optically guided entry approach in laparoscopic surgery. Materials The clinical data from a personal series of 821 consecutive cases of laparoscopic surgery were used. Methods The technique of an optically guided primary entry using an Endopath Xcel trocar was described. Results There was no bowel, vascular, or visceral complication in this series. This entry approach was also safe in those with high surgical risks, for example, high body mass index, multiple previous abdominal surgeries and previous laparotomy. There was no failed entry, no extraperitoneal insufflation, no wound infection and wound hernia. Conclusion In this personal series, the findings demonstrated the safety and feasibility of an optically guided entry technique in laparoscopic surgeries.