Comparing the novel microstream and the traditional mainstream method of end-tidal CO2 monitoring with respect to PaCO2 as gold standard in intubated critically ill children

The objective of this study was to evaluate a novel microstream method by comparison with PaCO 2 and the more standard mainstream capnometer in intubated pediatric patients. We hypothesized that the novel microstream method would superior compared to the traditional mainstream method in predicting P...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2020-12, Vol.10 (1), p.22042-22042, Article 22042
Hauptverfasser: Duyu, Muhterem, Bektas, Anıl Dogan, Karakaya, Zeynep, Bahar, Meral, Gunalp, Aybuke, Caglar, Yasemin Mocan, Yersel, Meryem Nihal, Bozkurt, Ozlem
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The objective of this study was to evaluate a novel microstream method by comparison with PaCO 2 and the more standard mainstream capnometer in intubated pediatric patients. We hypothesized that the novel microstream method would superior compared to the traditional mainstream method in predicting PaCO 2 . This was a prospective single-center comparative study. The study was carried out on 174 subjects with a total of 1338 values for each method. Data were collected prospectively from mainstream and microstream capnometer simultaneously and compared with PaCO 2 results. Although both mainstream PetCO 2 (mainPetCO 2 ) and microstream PetCO 2 (microPetCO 2 ) were moderately correlated (r = 0.63 and r = 0.68, respectively) with PaCO 2 values, mainPetCO 2 was in better agreement with PaCO 2 in all subjects (bias ± precision values of 3.8 ± 8.9 and 7.3 ± 8.2 mmHg, respectively). In those with severe pulmonary disease, the mainPetCO 2 and microPetCO 2 methods were highly correlated with PaCO 2 (r = 0.80 and r = 0.81, respectively); however, the biases of both methods increased (14.8 ± 9.1 mmHg and 16.2 ± 9.0 mmHg, respectively). In cases with increased physiologic dead space ventilation, the agreement levels of mainPetCO 2 and microPetCO 2 methods became distorted (bias ± precision values of 20.9 ± 11.2 and 25.0 ± 11.8 mm Hg, respectively) even though mainPetCO 2 and microPetCO 2 were highly correlated (r = 0.78 and r = 0.78, respectively). It was found that the novel microstream capnometer method for PetCO 2 measurements provided no superiority to the traditional mainstream method. Both capnometer methods may be useful in predicting the trend of PaCO 2 due to significant correlations with the gold standard measurement in cases with severe pulmonary disease or increased physiological dead space –despite reduced accuracy.
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-020-79054-y