Evaluation of modulus of elasticity in static bending of particleboards manufactured with Eucalyptus grandis wood and oat hulls

The aim of this study was to determine the modulus of elasticity (MOE) in static bending using two different calculation methods, a simple one based on Brazilian standard ABNT NBR 14810 (ABNT, 2006), and an alternative one, based on the Least Squares Method, and evaluate whether there is statistical...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta scientiarum. Technology 2014-02, Vol.36 (3), p.405-411
Hauptverfasser: Varanda, Luciano Donizeti, Christoforo, André Luis, Almeida, Diego Henrique de, Silva, Diogo Aparecido Lopes, Panzera, Túlio Hallak, Lahr, Francisco Antonio Rocco
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to determine the modulus of elasticity (MOE) in static bending using two different calculation methods, a simple one based on Brazilian standard ABNT NBR 14810 (ABNT, 2006), and an alternative one, based on the Least Squares Method, and evaluate whether there is statistical equivalence between these MOE calculation methods. The alternative method employed results obtained from static bending tests at three-points, with three dial gauges, non-destructively, by imposing limits on two displacements (L 300-1 and L 200-1), where L is the specimen length. Results of confidence intervals indicated statistical equivalence between MOE values obtained by means of both methods, thus corroborating the simple mathematical model proposed by ABNT NBR14810 (ABNT, 2006). Panels produced with up to 15% oat hulls (Treatments 1 to 6) showed the highest average MOE values. The methods employed to obtain MOE in static bending were statistically equivalent. However, in addition to being non-destructive, the alternative method proposed here in provided more reliable results, just by taking into account more measures along the specimens.
ISSN:1806-2563
1807-8664