Endocyclophotocoagulation Combined with Phacoemulsification in Glaucoma Treatment: Five-Year Results

this study aimed to assess the effectiveness and safety of phaco-endocyclophotocoagulation (phaco-ECP) in patients with glaucoma over five consecutive years. Thirty-eight patients (38 eyes) with primary and secondary glaucoma were enrolled to undergo phaco-ECP (Endo Optiks URAM E2, Beaver-Visitec In...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedicines 2024-01, Vol.12 (1), p.186
Hauptverfasser: Bolek, Bartłomiej, Wylęgała, Adam, Rebkowska-Juraszek, Małgorzata, Wylęgała, Edward
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:this study aimed to assess the effectiveness and safety of phaco-endocyclophotocoagulation (phaco-ECP) in patients with glaucoma over five consecutive years. Thirty-eight patients (38 eyes) with primary and secondary glaucoma were enrolled to undergo phaco-ECP (Endo Optiks URAM E2, Beaver-Visitec International, Waltham, MA, USA). The primary outcome measures were intraocular pressure (IOP) reduction, success rates, glaucoma medication use, and visual acuity after phaco-ECP. An IOP reduction of 20% compared to the baseline value without re-intervention was considered a successful treatment. Complete success was defined as a cessation of antiglaucoma medications. Secondary outcome measures included intraoperative and postoperative complications. Measurements were performed preoperatively and in the first week and 1, 3, 6, 12, 18, 24, 30, 36, 42, 48, 54, and 60 months postoperatively. The mean ± SD values of IOP preoperatively, at 12, 24, 36, 48, and 60 months postoperatively were 22.6 ± 6.7 mmHg, 15.9 ± 3.9 mmHg ( < 0.001), 15.9 ± 2.9 mmHg ( < 0.001), 15.6 ± 2.7 mmHg ( < 0.001), 15.5 ± 3.8 mmHg ( < 0.001), and 15.2 ± 2.6 mmHg ( < 0.001), respectively. The mean IOP at the last follow-up was reduced by 32.7%. The decrease in the number of antiglaucoma medications was statistically significant at each follow-up visit compared to the baseline. The qualified success rate was 40.6%. All patients at the 60-month follow-up visit required the use of antiglaucoma medications-none of the patients achieved complete success. During the follow-up period, nine patients (28.3%) that required retreatment due to nonachievement of the target IOP were considered failures. Six patients (15.8%) were lost from the follow-up. A total of 23 patients were evaluated 60 months after their phaco-ECP. Complications directly associated with the procedure, such as corneal edema (25.6%), IOP spikes (20.5%), IOL dislocation (2.6%), and uveitis (12.8%), were observed in our patients. Hypotony was not observed in any of our patients. The phaco-ECP procedure was effective, well-tolerated, and safe for reducing IOP in glaucoma patients with cataracts over a long-term follow-up. Randomized, larger-scale studies are required to validate the results obtained.
ISSN:2227-9059
2227-9059