Simultaneous detection and differentiation of SARS-CoV-2, influenza A virus and influenza B virus by one-step quadruplex real-time RT-PCR in patients with clinical manifestations
•A one-step quadruplex rRT-PCR assay with TaqMan probes to detect SARS-CoV-2, influenza A and B virus was validated.•The assay showed 100% specificity with R2≥0.9846, CVs≤5.32%, and amplification efficiency ≥86.1% for target genes.•The assay has perfect performance on different types of clinical spe...
Gespeichert in:
Veröffentlicht in: | International journal of infectious diseases 2021-02, Vol.103, p.517-524 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •A one-step quadruplex rRT-PCR assay with TaqMan probes to detect SARS-CoV-2, influenza A and B virus was validated.•The assay showed 100% specificity with R2≥0.9846, CVs≤5.32%, and amplification efficiency ≥86.1% for target genes.•The assay has perfect performance on different types of clinical specimens.•The quadruplex rRT-PCR assays will assist in identification and differentiation of suspected cases of COVID-19 and influenza.
To develop a novel quadruplex real-time reverse transcription polymerase chain reaction (rRT-PCR) assay for the diagnosis of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, differential diagnosis and detection of co-infections.
A one-step quadruplex rRT-PCR assay was developed for simultaneous detection and differentiation of SARS-CoV-2 ORF1ab and N genes, influenza A virus (hIAV) and influenza B virus (hIBV).
The quadruplex rRT-PCR assay had good sensitivity and specificity. Correlation coefficients and amplification efficiencies of all singleplex and quadruplex rRT-PCR reactions were within acceptable ranges. The 95% lower limits of detection for plasmid standards and positive nucleic acid extracts of the quadruplex rRT-PCR assay were 57.38–95.11 copies/μL and 114.65–154.25 copies/μL, respectively. Excellent results were attained for inter- and intra-assay reproducibility. Among these clinical samples, only four samples showed results inconsistent with the singleplex rRT-PCR assays.
To the authors’ knowledge, this is the first study to report a quadruplex rRT-PCR assay for the detection of two SARS-CoV-2 genes, hIAV and hIBV with perfect clinical performance. |
---|---|
ISSN: | 1201-9712 1878-3511 |
DOI: | 10.1016/j.ijid.2020.12.027 |