Temporal reverse flow by proximal femoral artery occlusion during drug-coated balloon dilatation: a technique to minimize downstream particle embolization and systemic adverse effects
Downstream paclitaxel particle embolization for nonhealing ischemic ulcers and systemic adverse effects caused by a paclitaxel drug-coated balloon are of concern, and safety measures to prevent these adverse risks are needed. To reduce distal particle embolization and movement of the paclitaxel part...
Gespeichert in:
Veröffentlicht in: | Journal of vascular surgery cases and innovative techniques 2021-12, Vol.7 (4), p.763-767 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Downstream paclitaxel particle embolization for nonhealing ischemic ulcers and systemic adverse effects caused by a paclitaxel drug-coated balloon are of concern, and safety measures to prevent these adverse risks are needed. To reduce distal particle embolization and movement of the paclitaxel particles to systemic blood flow during drug-coated balloon inflation, proximal balloon occlusion using a sheathless temporary occlusion balloon-guiding catheter and extraction by manual aspiration of the paclitaxel-containing blood through the catheter are good treatment options to overcome these risks. Here, we introduce this method with tips and tricks, and demonstrate initial experience of this technique. |
---|---|
ISSN: | 2468-4287 2468-4287 |
DOI: | 10.1016/j.jvscit.2021.10.001 |