Study of Image Classification Accuracy with Fourier Ptychography

In this research, the accuracy of image classification with Fourier Ptychography Microscopy (FPM) has been systematically investigated. Multiple linear regression shows a strong linear relationship between the results of image classification accuracy and image visual appearance quality based on PSNR...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied sciences 2021-05, Vol.11 (10), p.4500
Hauptverfasser: Zhang, Hongbo, Zhang, Yaping, Wang, Lin, Hu, Zhijuan, Zhou, Wenjing, Tsang, Peter W. M., Cao, Deng, Poon, Ting-Chung
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this research, the accuracy of image classification with Fourier Ptychography Microscopy (FPM) has been systematically investigated. Multiple linear regression shows a strong linear relationship between the results of image classification accuracy and image visual appearance quality based on PSNR and SSIM with multiple training datasets including MINST, Fashion MNIST, Cifar, Caltech 101, and customized training datasets. It is, therefore, feasible to predict the image classification accuracy only based on PSNR and SSIM. It is also found that the image classification accuracy of FPM reconstructed with higher resolution images is significantly different from using the lower resolution images under the lower numerical aperture (NA) condition. The difference is yet less pronounced under the higher NA condition.
ISSN:2076-3417
2076-3417
DOI:10.3390/app11104500