The New Sun-Sky-Lunar Cimel CE318-T Multiband Photometer - A Comprehensive Performance Evaluation
This paper presents the new photometer CE318-T, able to perform daytime and night-time photometric measurements using the sun and the moon as light source. Therefore,this new device permits a complete cycle of diurnal aerosol and water vapour measurements valuable to enhance atmospheric monitoring t...
Gespeichert in:
Veröffentlicht in: | Atmospheric measurement techniques 2016-02, Vol.9 (2), p.631-654 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presents the new photometer CE318-T, able to perform daytime and night-time photometric measurements using the sun and the moon as light source. Therefore,this new device permits a complete cycle of diurnal aerosol and water vapour measurements valuable to enhance atmospheric monitoring to be extracted. In this study wehave found significantly higher precision of triplets when comparing the CE318-T master instrument and the Cimel AErosol RObotic NET work (AERONET) master (CE318-AERONET) triplets as a result of the new CE318-T tracking system. Regarding the instrument calibration, two new methodologies to transfer the calibration from a reference instrument using only daytime measurements (Sun Ratio and Sun-Moon gain factor techniques) are presented and discussed. These methods allow the reduction of the previous complexities inherent to nocturnal calibration. A quantitative estimation of CE318-T AOD uncertainty by means of error propagation theory during daytime revealed AOD uncertainties (u(sup D)(sub AOD)) for Langley-calibrated instruments similar to the expected values for other reference instruments (0.002-0.009). We have also found u(sup D)(sub AOD) values similar to the values reported in sun photometry for field instruments (approximately 0.015). In the case of the night-time period, the CE318-T-estimated standard combined uncertainty (u(sup N)(sub AOD)) is dependent not only on the calibration technique but also on illumination conditions and the instrumental noise. These values range from 0.011-0.018 for Lunar Langley-calibrated instruments to 0.012-0.021 for instruments calibrated using the Sun Ratio technique. In the case of moon-calibrated instruments using the Sun-Moon gain factor method and sun calibrated using the Langley technique, we found u(sup N)(sub AOD) ranging from 0.016 to 0.017 (up to 0.019 in 440 nm channel), not dependent on any lunar irradiance model. A subsequent performance evaluation including CE318-T and collocated measurements from independent reference instruments has served to assess the CE318-T performance as well as to confirm its estimated uncertainty. Daytime AOD evaluation, performed at Izana station from March to June 2014, encompassed measurements from a reference CE318-T, a CE318-AERONET master instrument, a Precision Filter Radiometer (PFR) and a Precision Spectroradiometer (PSR) prototype, reporting low AOD discrepancies between the four instruments (up to 0.006). The nocturnal AOD evaluation was perf |
---|---|
ISSN: | 1867-8548 1867-1381 1867-8548 |
DOI: | 10.5194/amt-9-631-2016 |