Temperature Characteristics of Traditional Indirect Moxibustion and Electronic Moxibustion

BackgroundElectronic moxibustion (EM) was developed to minimize the side effects of traditional moxibustion, such as burns, and to overcome therapeutic compliances such as smoke or smell. ObjectivesTo investigate distributions and thermal stimulation of EM at various depths using silicon phantom and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of acupuncture and meridian studies 2022-06, Vol.15 (3), p.174-180
Hauptverfasser: Kim, Dong-Joo, Jo, Hyo-Rim, Jang, Hansol, Choi, Seong-Kyeong, Jung, Chan-Yung, Sung, Won-Suk, Lee, Seung-Deok, Lee, Byung-Wook, Kim, Eun-Jung
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BackgroundElectronic moxibustion (EM) was developed to minimize the side effects of traditional moxibustion, such as burns, and to overcome therapeutic compliances such as smoke or smell. ObjectivesTo investigate distributions and thermal stimulation of EM at various depths using silicon phantom and to compare this methodology to traditional indirect moxibustion (TIM). MethodsA silicon phantom composed of polydimethylsiloxane was heated and immersed in a hot plate containing warm water to set the phantom's temperature to that of biological tissue. K-type thermocouples were inserted into the phantom at depths of 0, 2, 5, 7, and 10 mm to measure temperature changes with thermal stimulation of EM or TIM placed on top of the phantom. ResultsAt the surface of the phantom, the peak temperature after applying TIM (55.04 ± 0.92℃ [Δ23.79 ± 0.96℃]) was significantly higher than after EM (43.25 ± 1.95℃ [Δ13.00 ± 2.23℃]), with both interventions reaching the highest temperature after 2 minutes. The temperature increase for TIM was also statistically significant compared to EM when measured at a depth of 2 mm. For the experimental setting with TIM, after reaching peak surface temperature, a rapid decrease was observed at the surface and 2 mm while EM showed a much more gradual decline. There was no significant difference in temperature change between the groups at depths of 5, 7, and 10 mm. ConclusionTIM resulted in a higher temperature rise compared to EM at the surface and at a 2 mm depth reaching over 50℃, which creates risk of burns. Thermal stimulation with EM had a lower risk of burns with temperature increment not being statistically different from TIM below the depth of 5 mm.
ISSN:2005-2901
2093-8152
DOI:10.51507/j.jams.2022.15.3.174