Research on force control system of lead cathode leveler

The flatness of the lead cathode plate affects the electrolytic efficiency of lead and the production efficiency of the whole lead electrolytic industry. However, the dynamic response of the force control system of the leveler is slow, and the anti-interference and robustness are poor. By comparing...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Metalurgija 2024-01, Vol.63 (1), p.117-120
Hauptverfasser: Y. F. Wang, Q. Q. Yin, Y. Q. Cai
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The flatness of the lead cathode plate affects the electrolytic efficiency of lead and the production efficiency of the whole lead electrolytic industry. However, the dynamic response of the force control system of the leveler is slow, and the anti-interference and robustness are poor. By comparing proportion integration differentiation (PID) control and feedback linearized synovial control two control strategies, MATLAB software was used for modeling and simulation analysis. The results show that the system with feedback linearized sliding mode control has faster response, higher precision and better robustness.
ISSN:0543-5846
1334-2576