Influence of a Novel Surface of Bioactive Implants on Osseointegration: A Comparative and Histomorfometric Correlation and Implant Stability Study in Minipigs

The objective of this study was to assess the influence of a novel surface of dental implants (ContacTi ) on the osseointegration process in a minipig model. The surface was compared with other existing surfaces on the market (SLA and SLActive ) by employing bone implant contact analysis (BIC) and i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of molecular sciences 2019-05, Vol.20 (9), p.2307
Hauptverfasser: Romero-Ruiz, Manuel M, Gil-Mur, Francisco Javier, Ríos-Santos, José Vicente, Lázaro-Calvo, Pedro, Ríos-Carrasco, Blanca, Herrero-Climent, Mariano
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The objective of this study was to assess the influence of a novel surface of dental implants (ContacTi ) on the osseointegration process in a minipig model. The surface was compared with other existing surfaces on the market (SLA and SLActive ) by employing bone implant contact analysis (BIC) and implant stability. Twelve minipigs were used with prior authorisation from an ethics committee. Three types of surfaces were tested: SLA (sand-blasted acid-etched titanium), SLActive (same but hydrophilic, performed under a nitrogen atmosphere), and ContacTi (alumina particle bombardment of titanium, bioactivated when treated thermochemically) in 4.1 mm × 8 mm implants with internal connection and a polished neck. Twelve implants of each surface type ( = 36) were placed, sacrificing 1/3 of the animals at 2 weeks of placement, 1/3 at 4 weeks and the remaining 1/3 at 8 weeks. Numerical variables were compared with Analysis of Variance, and the correlation between ISQ and BIC was established with the Spearman's rank correlation coefficient. SLActive and ContacTi surfaces showed elevated osteoconductivity at 4 weeks, maintaining a similar evolution at 8 weeks (large amount of mature lamellar tissue with high maturity and bone quality). The SLA surface showed slower maturation. The ISQ values in surgery were elevated (above 65), higher at necropsy and higher at 4 and 8 weeks in the SLA group than in the other two (SLActive and ContacTi ). No significant correlation was found between ISQ and BIC for each implant surface and necropsy time. The three surfaces analysed showed high RFA and BIC values, which were more favourable for the SLActive and ContacTi surfaces. No statistical correlation was found between the RFA and BIC values in any of the three surfaces analysed.
ISSN:1422-0067
1661-6596
1422-0067
DOI:10.3390/ijms20092307