How reproducible are clinical measurements in robotic knee surgery?
Purpose Robotic-assisted surgery has been recently introduced to improve biomechanical restoration, and thus better clinical and functional outcomes, after knee joint arthroplasty operations. Robotic-assisted uni-compartmental knee arthroplasty (UKA) aims indeed to improve surgical bone resection an...
Gespeichert in:
Veröffentlicht in: | Journal of Experimental Orthopaedics 2023-03, Vol.10 (1), p.32-n/a |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
Robotic-assisted surgery has been recently introduced to improve biomechanical restoration, and thus better clinical and functional outcomes, after knee joint arthroplasty operations. Robotic-assisted uni-compartmental knee arthroplasty (UKA) aims indeed to improve surgical bone resection and alignment accuracy, optimized component positioning and knee balancing, relying on a series of calibration measurements performed during the surgery. These advantages focus therefore on improving the reproducibility of UKA surgeries, reducing (if not eliminating) eventual differences among high- and low-volume surgeons.
The purpose of this study is to investigate and quantify the reproducibility of in-vivo measurements performed with a robotic system: the intra- and inter-observer variability of a series of measurements was therefore analyzed and compared among differently experienced operators.
Methods
Five patients were analyzed and underwent robotic-assisted UKA using a semi-active robotic system.
Three different observers with different experience levels were involved to independently perform the measurements of two parameters of the preoperative knee (Hip-Knee-Ankle angle [HKAa], Internal-External Rotation) at different degrees of knee flexion. Inter-observer and intra-observer comparisons were performed.
Results
The average variability in the measurements obtained from the intra-observer and inter-observer comparisons were always 0.60) in the remaining ones.
Conclusion
This study demonstrated high reproducibility of the measurements obtainable in clinical environment with the robotic system. The inter-observer results furthermore showed that the level of confidence with the robotic system is not significantly influencing the measurement. |
---|---|
ISSN: | 2197-1153 2197-1153 |
DOI: | 10.1186/s40634-023-00582-3 |