A multisite validation of a two hours antibiotic susceptibility flow cytometry assay directly from positive blood cultures

Rapid antimicrobial susceptibility testing (AST) is urgently needed to provide safer treatment to counteract antimicrobial resistance. This is critical in septic patients, because resistance increases empiric therapy uncertainty and the risk of a poor outcome. We validate a novel 2h flow cytometry A...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC microbiology 2024-05, Vol.24 (1), p.187-10, Article 187
Hauptverfasser: Pina-Vaz, C, Silva-Dias, A, Martins-Oliveira, I, Gomes, R, Perez-Viso, B, Cruz, S, Rodrigues, A G, Sarmento, A, Cantón, R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Rapid antimicrobial susceptibility testing (AST) is urgently needed to provide safer treatment to counteract antimicrobial resistance. This is critical in septic patients, because resistance increases empiric therapy uncertainty and the risk of a poor outcome. We validate a novel 2h flow cytometry AST assay directly from positive blood cultures (PBC) by using a room temperature stable FASTgramneg and FASTgrampos kits (FASTinov® Porto, Portugal) in three sites: FASTinov (site-1), Hospital Ramon y Cajal, Madrid, Spain (site-2) and Centro Hospitalar S. João, Porto, Portugal (site-3). A total of 670 PBC were included: 333 spiked (site-1) and 337 clinical PBC (151 site-2 and 186 site-3): 367 gram-negative and 303 gram-positive. Manufacturer instructions were followed for sample preparation, panel inoculation, incubation (1h/37ºC) and flow cytometry analysis using CytoFlex (Site-1 and -2) or DxFlex (site-3) both instruments from Beckman-Coulter, USA. A proprietary software (bioFAST) was used to immediately generate a susceptibility report in less than 2 h. In parallel, samples were processed according to reference AST methods (disk diffusion and/or microdilution) and interpreted with EUCAST and CLSI criteria. Additionally, ten samples were spiked in all sites for inter-laboratory reproducibility. Sensitivity and specificity were >95% for all antimicrobials. Reproducibility was 96.8%/95.0% for FASTgramneg and 95.1%/95.1% for FASTgrampos regarding EUCAST/CLSI criteria, respectively. FASTinov® kits consistently provide ultra-rapid AST in 2h with high accuracy and reproducibility on both Gram-negative and Gram-positive bacteria. This technology creates a new paradigm in bacterial infection management and holds the potential to significantly impact septic patient outcomes and antimicrobial stewardship.
ISSN:1471-2180
1471-2180
DOI:10.1186/s12866-024-03341-1