Long-term safety and absorption assessment of a novel bioresorbable nitrided iron scaffold in porcine coronary artery

This study aimed to investigate the long-term biocompatibility, safety, and degradation of the ultrathin nitrided iron bioresorbable scaffold (BRS) in vivo, encompassing the whole process of bioresorption in porcine coronary arteries. Fifty-two nitrided iron scaffolds (strut thickness of 70 μm) and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bioactive materials 2022-11, Vol.17, p.496-505
Hauptverfasser: Zheng, Jian-Feng, Xi, Zi-Wei, Li, Yang, Li, Jia-Nan, Qiu, Hong, Hu, Xiao-Ying, Luo, Tong, Wu, Chao, Wang, Xin, Song, Lai-Feng, Li, Li, Qi, Hai-Ping, Zhang, Gui, Qin, Li, Zhang, Wan-Qian, Shi, Xiao-Li, Wang, Shu-Han, Zhang, De-Yuan, Xu, Bo, Gao, Run-Lin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to investigate the long-term biocompatibility, safety, and degradation of the ultrathin nitrided iron bioresorbable scaffold (BRS) in vivo, encompassing the whole process of bioresorption in porcine coronary arteries. Fifty-two nitrided iron scaffolds (strut thickness of 70 μm) and 28 Vision Co–Cr stents were randomly implanted into coronary arteries of healthy mini-swine. The efficacy and safety of the nitrided iron scaffold were comparable with those of the Vision stentwithin 52 weeks after implantation. In addition, the long-term biocompatibility, safety, and bioresorption of the nitrided iron scaffold were evaluated by coronary angiography, optical coherence tomography, micro-computed tomography, scanning electron microscopy, energy dispersive spectrometry and histopathological evaluations at 4, 12, 26, 52 weeks and even at 7 years after implantation. In particular, a large number of struts were almost completely absorbed in situ at 7 years follow-up, which were first illustrated in this study. The lymphatic drainage pathway might serve as the potential clearance way of iron and its corrosion products. [Display omitted] •This study investigated the long-term safety and the total degradative process of nitrided iron scaffold in porcine coronary artery.•The safety and biocompatibility of the nitrided iron scaffold were comparable to those of the Vision stent within 12 months after implantation.•This ultrathin nitrided iron scaffold can be degraded and bioresorbed completely with long-term biocompatibility in porcine coronary artery.•Interestingly, the lymphatic metabolic pathway might serve as the potential absorption route for iron and its corrosion products.
ISSN:2452-199X
2452-199X
DOI:10.1016/j.bioactmat.2022.01.005