Mitigation of Current Distortion for GaN-Based CRM Totem-Pole PFC Rectifier With ZVS Control
The GaN-based critical conduction mode (CRM) totem-pole power factor correction (PFC) converter with full-line-cycle zero voltage switching (ZVS) is a promising candidate for high-efficiency front-end rectifiers. However, the input current can be degraded by line-cycle current distortion and ac line...
Gespeichert in:
Veröffentlicht in: | IEEE open journal of power electronics 2021, Vol.2, p.290-303 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The GaN-based critical conduction mode (CRM) totem-pole power factor correction (PFC) converter with full-line-cycle zero voltage switching (ZVS) is a promising candidate for high-efficiency front-end rectifiers. However, the input current can be degraded by line-cycle current distortion and ac line zero-crossing current spikes, and maintaining reliable ZVS control is difficult in noise-susceptible high-frequency environments. In this paper, a detailed analysis of the current distortion issues in a GaN-based CRM totem-pole PFC with digital ZVS control is provided, and effective approaches are proposed to mitigate different kinds of current distortion and ensure stable ZVS control under high-frequency operation. The proposed solutions have the advantages of straightforward implementation and do not increase the control complexity. The current distortion issues are demonstrated in two GaN-based CRM totem-pole PFC prototypes, a 1.5 kW PFC for data centers and a 100 W PFC in a 6.78 MHz wireless charging power supply for consumer electronics. The proposed methods are experimentally verified with effective mitigation of the current distortion and improvement of the converter power efficiency. |
---|---|
ISSN: | 2644-1314 2644-1314 |
DOI: | 10.1109/OJPEL.2021.3071213 |