Thermal performance of plastic receiver in solar collector
A plastic tubes used as absorber of active flat plate solar collector (FPSC) for heating water were studied numerically and experimentally. The set-up is located in Babylon (republic of Iraq) 43.80 East longitude and 32.3 0 North latitude with titled of 450 toward the south direction. The study invo...
Gespeichert in:
Veröffentlicht in: | Journal of Engineering 2019-06, Vol.25 (7), p.37-60 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A plastic tubes used as absorber of active flat plate solar collector (FPSC) for heating
water were studied numerically and experimentally. The set-up is located in Babylon
(republic of Iraq) 43.80 East longitude and 32.3
0 North latitude with titled of 450
toward the south direction. The study involved three dimensions mathematical model
for flat coil plastic absorber which solved by FLUENT-ANSYS-R.18 program.
Experiments were conducted at outdoor conditions for clear days on January and
February 2018 with various water volume flow rates namely (500, 750, 1000, 1250,
and 1500 Liter per hour LPH) on each month for Reynolds number range of (1 x 104
to 5 x 104
) through the receiver. The experimental results showed improvement in
absorber input - output temperature difference, collector efficiency, and water storage
temperature; the maximum input - output temperature difference is 3.1 °C, the
maximum collector efficiency is 79%, and the maximum water storage temperature is
67 °C. The comparison validates a good agreement between the numerical and
experimental results at variable operation conditions with maximum deviation of
4.2%. Also the experimental results were compared with previous study for similar
condition and gave a good improvement |
---|---|
ISSN: | 1726-4073 2520-3339 |
DOI: | 10.31026/j.eng.2019.07.03 |