Enhanced Specificity in Loop-Mediated Isothermal Amplification with Poly(ethylene glycol)-Engrafted Graphene Oxide for Detection of Viral Genes
Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification method that allows the simple, quick, and low-cost detection of various viral genes. LAMP assays are susceptible to generating non-specific amplicons, as high concentrations of DNA primers can give rise to primer dimerizat...
Gespeichert in:
Veröffentlicht in: | Biosensors (Basel) 2022-08, Vol.12 (8), p.661 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification method that allows the simple, quick, and low-cost detection of various viral genes. LAMP assays are susceptible to generating non-specific amplicons, as high concentrations of DNA primers can give rise to primer dimerization and mismatched hybridizations, resulting in false-positive signals. Herein, we reported that poly(ethylene glycol)-engrafted nanosized graphene oxide (PEG-nGO) can significantly enhance the specificity of LAMP, owing to its ability to adsorb single-stranded DNA (ssDNA). By adsorbing surplus ssDNA primers, PEG-nGO minimizes the non-specific annealing of ssDNAs, including erroneous priming and primer dimerization, leading to the enhanced specificity of LAMP. The detection of complementary DNAs transcribed from the hepatitis C virus (HCV) RNA was performed by the PEG-nGO-based LAMP. We observed that the inclusion of PEG-nGO significantly enhances the specificity and sensitivity of the LAMP assay through the augmented difference in fluorescence signals between the target and non-target samples. The PEG-nGO-based LAMP assay greatly facilitates the detection of HCV-positive clinical samples, with superior precision to the conventional quantitative real-time PCR (RT-qPCR). Among the 20 clinical samples tested, all 10 HCV-positive samples are detected as positive in the PEG-nGO-based LAMP, while only 7 samples are detected as HCV-positive in the RT-qPCR. In addition, the PEG-nGO-based LAMP method significantly improves the detection precision for the false-positive decision by 1.75-fold as compared to the LAMP without PEG-nGO. Thus, PEG-nGO can significantly improve the performance of LAMP assays by facilitating the specific amplification of target DNA with a decrease in background signal. |
---|---|
ISSN: | 2079-6374 2079-6374 |
DOI: | 10.3390/bios12080661 |