An experimental study for the effect of vertical forced vibration on pool boiling heat transfer coefficient
In this research, an experimental study for the effect of forced vibrations on pool boiling heat transfer coefficient has been made in glass of chamber cylindrical shape (75 mm bore and 300 mm length) and an electrical heater inside it (12 mm diameter and 80 mm length) to heat the distilled water at...
Gespeichert in:
Veröffentlicht in: | Engineering and Technology Journal 2012-06, Vol.30 (10), p.1662-1676 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this research, an experimental study for the effect of forced vibrations on pool boiling heat transfer coefficient has been made in glass of chamber cylindrical shape (75 mm bore and 300 mm length) and an electrical heater inside it (12 mm diameter and 80 mm length) to heat the distilled water at different values of heat flux (27.521 kW/m2-53.08 kW/m2) utilized to perform this work. The experimental study is carried out at a range of frequencies (2-40 Hz) and at a range of amplitude (1.8-3.5 mm)The result obtained showed that the pool boiling heat transfer coefficient is increasing with increasing the vibration frequency within a range of (2-14 Hz), compared with that heat transfer without frequency. And, the maximum enhancement ratio is about 250% at 5 Hzand q"=27.521 kW/m2, 231%at 6 Hz and q"=36.727 kW/m2, 181% at 6 Hz and q"=41.83 kW/m2and 93% at 8 Hz and q"=53.08 kW/m2. In general, it is found that the difference in the temperature has been maintained at the highest value of vibration frequency range of (14-40 Hz), and the value of heat transfer coefficient is significantly increasing with increasing the vibration Reynolds number (Rev).The effect of vibration frequency has improved not only the boiling heat transfer coefficient, but also led to improve the amount of heat drawn by the cooling water (condensation) by increasing the amount of falling drops. The following empirical relations have been obtained between the experimental heat transfer coefficient with vibration (hv) and some of important parameters, such as excess temperature(∆Texsses) in oC, input heat flux (q") in (W/m2), and vibration frequency (f) in Hz:hv=0.246912 × f0.16534× ∆T-0.92429× q"1.0727nd, the second correlation is (hv) with Reynolds vibration effect (Rev) and input heat flux (q") in(kW/m2)hv=499.747×Rev0.3576×q"-2.14
تناول هذا البحث إجراء دراسة عملية لبيان تأثير الاهتزازات القسرية الشاقولية على معامل انتقال الحرارة بالغليان الحوضي في داخل زجاجة إسطوانية الشكل ارتفاعها (300 mm) و قطرها (75 mm) لها قاعدتان من النيكل المطلي عند نهايتها و تحتوي بداخلها سخان كهربائي (heater) أسطواني الشكل طوله (80 mm) و قطره (12 mm) مثبت بالقاعدة السفلية للأسطوانة يقوم بتسخين الماء المقطر لقيم فيض حراري تتراوح بين (27.521 kW/m2) إلى (53.08 kW/m2) أعدت لهذا الغرض. تمت الدراسة تحت تأثير معدل اهتزازات يتراوح بين (2-40 Hz) و قيم السعات الاهتزازية تتراوح بين (1.8-3.5 mm).
النتائج التي تم التوصل لها بينت زيادة معامل انتقال الحرارة بالغليان الحوضي مع زيادة الترددات الاهتزازية من (2-14 Hz) و أعظم قيمة ل |
---|---|
ISSN: | 1681-6900 2412-0758 2412-0758 |