A NEW ANATOMICAL PLATE FOR EXTRA-ARTICULAR DISTAL HUMERAL FRACTURES: BIOMECHANICAL STUDY

We compared the mechanical properties of two fixation techniques for the treatment of extra-articular distal third humeral fractures. Two groups were created from twenty-four humeri. Group 1 was instrumented using a new, precontoured, 8-hole (3.5-mm-diameter) locking compression plate (LCP) placed a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta ortopedica brasileira 2022-01, Vol.30 (1), p.e248473-e248473
Hauptverfasser: Mutlu, Harun, Polat, Abdulkadir, Çetin, Mehmet Ümit, Mutlu, Serhat, Demir, Teyfik, Parmaksizoğlu, Atilla Sancar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We compared the mechanical properties of two fixation techniques for the treatment of extra-articular distal third humeral fractures. Two groups were created from twenty-four humeri. Group 1 was instrumented using a new, precontoured, 8-hole (3.5-mm-diameter) locking compression plate (LCP) placed anterolaterally. Group 2 was instrumented using an 8-hole (3.5-mm-diameter) precontoured posterolateral LCP plate placed on the distal humerus. Four-point bending tests and torsion tests were performed until the specimens broke. The four-point bending stiffness test showed that the stiffness of anterolaterally fixed humeri was significantly higher than that of posterolaterally fixed humeri (p
ISSN:1413-7852
1809-4406
1809-4406