Transient analysis of power transmission towers above lossy ground with frequency dependent electrical parameters considering the water content of soil

•The effect of water content on soil electrical parameters is investigated.•Three soil models proposed in the literature are studied.•Ground Potential Rise is significantly influenced by this physical factor.•Backflashover probability is reduced when the water content is considered in the analysis.•...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:e-Prime 2023-06, Vol.4, p.100161, Article 100161
Hauptverfasser: de Azevedo, Walter Luiz Manzi, de Araújo, Anderson Ricardo Justo, Colqui, Jaimis Sajid Leon, Filho, José Pissolato, Kordi, Behzad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•The effect of water content on soil electrical parameters is investigated.•Three soil models proposed in the literature are studied.•Ground Potential Rise is significantly influenced by this physical factor.•Backflashover probability is reduced when the water content is considered in the analysis.•The available soil models provide distinct transient responses which may affect the protection operation against lightning strikes. Adequate soil modeling is fundamental to assessing the grounding impedance of the grounding system and the transient responses in power systems. This paper aims to investigate three soil models with electrical parameters varying with frequency and water content, namely Smith-Longmire, Scott, and Messier models, and their impact on the ground potential rise (GPR) waveforms of vertical grounding rods. Besides that, the transient induced voltages across the string of insulators induced are also investigated for lightning currents representative first, and subsequent return strokes are employed. The harmonic grounding impedance (HGI) is calculated for rods of 3, 15, and 30 m buried in frequency-dependent (FD) soil model using commercial electromagnetic software (FEKO) with the Method of Moments (MoM) for a range of 100 Hz to 10 MHz. Simulation results show a significant modification of the calculated HGI beyond a particular frequency. The induced transient GPR waveforms show a notable reduction in their voltage peaks when the FD soil model is compared with those computed using the frequency-independent (FI) soil model. Finally, a backflashover analysis is carried out that demonstrates its dependence on the rod length, water content, and the specific soil model employed.
ISSN:2772-6711
2772-6711
DOI:10.1016/j.prime.2023.100161