Performance Evaluation of Harmonic Reduced Non-Overlap Winding Wound Rotor Synchronous Machine
The analysis and performance evaluation of a harmonic reduction strategy of a non-overlap winding wound rotor synchronous machine is conducted in this paper. The harmonic reduction strategy utilizes phase-shifts between coil currents to reduce sub- and higher-order harmonics. The design is performed...
Gespeichert in:
Veröffentlicht in: | Energies (Basel) 2021-11, Vol.14 (22), p.7501 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The analysis and performance evaluation of a harmonic reduction strategy of a non-overlap winding wound rotor synchronous machine is conducted in this paper. The harmonic reduction strategy utilizes phase-shifts between coil currents to reduce sub- and higher-order harmonics. The design is performed on a 3 MW wound rotor synchronous machine with a 16/18 pole/slot combination. The application results in a lowered torque ripple and an increased efficiency of the designed machine. The manufacturing and testing of a 3 kW prototype to ascertain the effectiveness of the design is also presented. The practical measurements correlate successfully with the theoretical results. |
---|---|
ISSN: | 1996-1073 1996-1073 |
DOI: | 10.3390/en14227501 |