Mode Recognition and Fault Positioning of Permanent Magnet Demagnetization for PMSM
This paper proposes a demagnetization fault detection, mode recognition, magnetic pole positioning, and degree evaluation method for permanent magnet synchronous motors. First, the analytical model of the single-coil no-load back electromotive force (EMF) of demagnetization fault for Permanent magne...
Gespeichert in:
Veröffentlicht in: | Energies (Basel) 2019, Vol.12 (9), p.1644 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper proposes a demagnetization fault detection, mode recognition, magnetic pole positioning, and degree evaluation method for permanent magnet synchronous motors. First, the analytical model of the single-coil no-load back electromotive force (EMF) of demagnetization fault for Permanent magnet synchronous motor (PMSM) arbitrary magnetic poles is established. In the analytical model, the single-coil no-load back EMF residual of the health state and the single magnetic pole sequential demagnetization fault are calculated and normalized. Model results are used as the fault sample database. Second, the energy interval database of the single-coil no-load back EMF residual with different numbers of magnetic pole demagnetization is established. Demagnetization fault detection and degree evaluation are performed by the real-time acquired amplitudes of the single-coil no-load back EMF residual. The number of demagnetization poles is determined by comparing the energy of the single-coil no-load back EMF residual with the energy interval database. Demagnetization mode recognition and magnetic pole positioning are realized by analyzing the correlation coefficients between normalized the single-coil no-load back EMF residual and the fault sample database. Finally, results of analysis of the finite element simulation validate the feasibility and effectiveness of the proposed method. |
---|---|
ISSN: | 1996-1073 1996-1073 |
DOI: | 10.3390/en12091644 |