Biomechanical analysis of a double fixation method for tendon graft in porcine tibia – using an interference screw plus staple
The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n=17), an...
Gespeichert in:
Veröffentlicht in: | Revista brasileira de ortopedia 2018-09, Vol.53 (5), p.564-569 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model.
Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n=17), and Group 2, fixation with interference screw and staple (n=19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10mm (F10), yield load (Fy), and stiffness.
The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups.
The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.
Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal.
Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10mm (F10), yield load (Fy) e rigidez.
Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos.
A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema. |
---|---|
ISSN: | 2255-4971 1982-4378 2255-4971 |
DOI: | 10.1016/j.rboe.2018.07.003 |