A novel use of the endoscopic cyclophotocoagulative probe for the management of excisional goniotomy induced chronic recurrent hyphema
To describe the management of a case of chronic, recurrent hyphema following excisional goniotomy with the Kahook Dual Blade. One week following uncomplicated surgery, the patient presented with eye pain, elevated intraocular pressure, and layered hyphema. The hyphema resolved with conservative meas...
Gespeichert in:
Veröffentlicht in: | American journal of ophthalmology case reports 2022-06, Vol.26, p.101492, Article 101492 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To describe the management of a case of chronic, recurrent hyphema following excisional goniotomy with the Kahook Dual Blade.
One week following uncomplicated surgery, the patient presented with eye pain, elevated intraocular pressure, and layered hyphema. The hyphema resolved with conservative measures but recurred several times with similar symptoms over the next several months. An attempt to stenose the “oozing” collector channel using the argon laser was unsuccessful. Treatment of the angle with an endoscopic semi-conductor diode laser (endoscopic cyclophotocoagulative or ECP) probe successfully altered the angle preventing further episodes of recurrent hyphema. The primary glaucoma procedure failed necessitating a filtering procedure.
Clinician should be aware of this potential complication, its treatment options, and outcomes. |
---|---|
ISSN: | 2451-9936 2451-9936 |
DOI: | 10.1016/j.ajoc.2022.101492 |