Analyzing the Resonance Resultant from the Capacitive Effects in Bulk Current Injection Probe

In this paper, the effect of the slot distance, existed between the two parts of BCI-probe shield, on its performance is studied, therefore, two ferrite materials with the same size and different characteristics are used to implement two identical BCI-probes. The input impedance and reflection coeff...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radioengineering 2020-04, Vol.29 (1), p.109-116
Hauptverfasser: Mashriki, I. M., Razavi, S. M. J., Armaki, S. H. M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, the effect of the slot distance, existed between the two parts of BCI-probe shield, on its performance is studied, therefore, two ferrite materials with the same size and different characteristics are used to implement two identical BCI-probes. The input impedance and reflection coefficient are measured for four different values of slot distance 0.5, 1, 2 and 3 mm. Practical results show a notable effect of the slot distance on measured quantities. Measured impedance analysis shows the appearance of three capacitive regions in its spectra, therefore, a three dimensional electromagnetic (EM) model is implemented in CST-Microwave Studio (MWS) software to disclose the main source parameters responsible for it. Results of achieved study, using developed EM model, were in accordance with measured data for the implemented prototypes, and showed the same resonance phenomena.
ISSN:1210-2512
DOI:10.13164/re.2020.0109