Improving lung cancer diagnosis by combining exhaled-breath data and clinical parameters

Exhaled-breath analysis of volatile organic compounds could detect lung cancer earlier, possibly leading to improved outcomes. Combining exhaled-breath data with clinical parameters may improve lung cancer diagnosis. Based on data from a previous multi-centre study, this article reports additional a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ERJ open research 2020-01, Vol.6 (1), p.221
Hauptverfasser: Kort, Sharina, Brusse-Keizer, Marjolein, Gerritsen, Jan Willem, Schouwink, Hugo, Citgez, Emanuel, de Jongh, Frans, van der Maten, Jan, Samii, Suzy, van den Bogart, Marco, van der Palen, Job
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Exhaled-breath analysis of volatile organic compounds could detect lung cancer earlier, possibly leading to improved outcomes. Combining exhaled-breath data with clinical parameters may improve lung cancer diagnosis. Based on data from a previous multi-centre study, this article reports additional analyses. 138 subjects with non-small cell lung cancer (NSCLC) and 143 controls without NSCLC breathed into the Aeonose. The diagnostic accuracy, presented as area under the receiver operating characteristic curve (AUC-ROC), of the Aeonose itself was compared with 1) performing a multivariate logistic regression analysis of the distinct clinical parameters obtained, and 2) using this clinical information beforehand in the training process of the artificial neural network (ANN) for the breath analysis. NSCLC patients (mean±sd age 67.1±9.1 years, 58% male) were compared with controls (62.1±7.0 years, 40.6% male). The AUC-ROC of the classification value of the Aeonose itself was 0.75 (95% CI 0.69-0.81). Adding age, number of pack-years and presence of COPD to this value in a multivariate regression analysis resulted in an improved performance with an AUC-ROC of 0.86 (95% CI 0.81-0.90). Adding these clinical variables beforehand to the ANN for classifying the breath print also led to an improved performance with an AUC-ROC of 0.84 (95% CI 0.79-0.89). Adding readily available clinical information to the classification value of exhaled-breath analysis with the Aeonose, either in a multivariate regression analysis or to the ANN, significantly improves the diagnostic accuracy to detect the presence or absence of lung cancer.
ISSN:2312-0541
2312-0541
DOI:10.1183/23120541.00221-2019