Flexural performance of laced reinforced concrete beams under static and fatigue loads
This paper introduces experimental results of eighteen simply supported reinforced concrete beams of cross sections (160 × 300) and length 3000 mm to study the effect of lacing reinforcement on the performance of such beams under static and fatigue loads. Twelve reinforced concrete beams (two of the...
Gespeichert in:
Veröffentlicht in: | Journal of Engineering 2019-09, Vol.25 (10), p.134-153 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper introduces experimental results of eighteen simply supported reinforced concrete
beams of cross sections (160 × 300) and length 3000 mm to study the effect of lacing
reinforcement on the performance of such beams under static and fatigue loads. Twelve
reinforced concrete beams (two of them are casted with vertical shear reinforcement used as
control beams) are tested under four points bending loading with displacement control
technique and six laced reinforced concrete beams were exposed to high frequency (10 Hz) by
fixing the fatigue load in each cycle. Three parameters are used in the designed beams, which
are: lacing bar diameter (4mm, 6mm, and 8mm), lacing bar inclination angle to
horizontal (30°
, 45°
and 60°
), and lacing steel ratio depending on number of lacing bar in each
longitudinal face of beam and lacing bar diameter. The comparison results of experimental tests
revealed that the ultimate loads of laced reinforced concrete beams are higher than the
conventional reinforced concrete beams due to increasing lacing bar diameter, angle of
inclination lacing bar, and lacing steel ratio, while the deflection is reduced. Also, the laced
reinforced concrete beams can safely withstand the fatigue loading |
---|---|
ISSN: | 1726-4073 2520-3339 |
DOI: | 10.31026/j.eng.2019.10.10 |