Degradation and de novo formation of nine major glucose degradation products during storage of peritoneal dialysis fluids
Reactive glucose degradation products (GDPs) are formed during heat sterilization of glucose-containing peritoneal dialysis fluids (PDFs) and may induce adverse clinical effects. Long periods of storage and/or transport of PDFs before use may lead to de novo formation or degradation of GDPs. Therefo...
Gespeichert in:
Veröffentlicht in: | Scientific reports 2022-03, Vol.12 (1), p.4268-11, Article 4268 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Reactive glucose degradation products (GDPs) are formed during heat sterilization of glucose-containing peritoneal dialysis fluids (PDFs) and may induce adverse clinical effects. Long periods of storage and/or transport of PDFs before use may lead to de novo formation or degradation of GDPs. Therefore, the present study quantified the GDP profiles of single- and double-chamber PDFs during storage. Glucosone, 3-deoxyglucosone (3-DG), 3-deoxygalactosone (3-DGal), 3,4-dideoxyglucosone-3-ene (3,4-DGE), glyoxal, methylglyoxal (MGO), acetaldehyde, formaldehyde, and 5-hydroxymethylfurfural (5-HMF) were quantified by two validated UHPLC-DAD methods after derivatization with
o
-phenylenediamine (dicarbonyls) or 2,4-dinitrophenylhydrazine (monocarbonyls). The PDFs were stored at 50 °C for 0, 1, 2, 4, 13, and 26 weeks. The total GDP concentration of single-chamber PDFs did not change considerably during storage (496.6 ± 16.0 µM, 0 weeks; 519.1 ± 13.1 µM, 26 weeks), but individual GDPs were affected differently. 3-DG (− 82.6 µM) and 3-DGal (− 71.3 µM) were degraded, whereas 5-HMF (+ 161.7 µM), glyoxal (+ 32.2 µM), and formaldehyde (+ 12.4 µM) accumulated between 0 and 26 weeks. Acetaldehyde, glucosone, MGO, and 3,4-DGE showed time-dependent formation and degradation. The GDP concentrations in double-chamber fluids were generally lower and differently affected by storage. In conclusion, the changes of GDP concentrations during storage should be considered for the evaluation of clinical effects of PDFs. |
---|---|