Transcatheter closure of hypertensive ductus with amplatzer post infarction muscular VSD occluder after percutaneous retrieval of embolized amplatzer duct occluder
Transcatheter closure of a large hypertensive patent ductus arteriosus is challenging with scant data about it. Even more challenging is retrieval of an embolized Amplatzer duct occluder. We report successful closure of a 12 mm large ductus with the Amplatzer muscular VSD occluder (post myocardial i...
Gespeichert in:
Veröffentlicht in: | Annals of pediatric cardiology 2014-05, Vol.7 (2), p.126-129 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Transcatheter closure of a large hypertensive patent ductus arteriosus is challenging with scant data about it. Even more challenging is retrieval of an embolized Amplatzer duct occluder. We report successful closure of a 12 mm large ductus with the Amplatzer muscular VSD occluder (post myocardial infarction) after percutaneous retrieval of the embolized, largest available, 16/14 mm Amplatzer duct occluder. |
---|---|
ISSN: | 0974-2069 0974-5149 |
DOI: | 10.4103/0974-2069.132481 |