Fluid velocity and LIF temperature measurement in a real model of heat exchanger
This article presents the results of temperature measurements in a real model of heat exchanger using LIF method. By the help of fluorescent dye Rhodamine B that responsive on the temperature variation is visualized the rate and warming - up of the liquid above the heating pipe. The drift excited by...
Gespeichert in:
Veröffentlicht in: | EPJ Web of conferences 2012-01, Vol.25, p.2009 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This article presents the results of temperature measurements in a real model of heat exchanger using LIF method. By the help of fluorescent dye Rhodamine B that responsive on the temperature variation is visualized the rate and warming - up of the liquid above the heating pipe. The drift excited by heat convection is measured by PIV method. The results of temperature field measurements are compared with metering affected by temperature probe. |
---|---|
ISSN: | 2100-014X 2100-014X |
DOI: | 10.1051/epjconf/20122502009 |