Portal Setup: the Key Point in the Learning Curve for Hip Arthroscopy Technique
Objective To analyze the learning curve experience of hip arthroscopy based on patient demographics, surgical time, portal setup time, and postoperative complications and to find the key point in the learning curve. Methods From May 2016 to February 2019, a prospective study on the learning curve ex...
Gespeichert in:
Veröffentlicht in: | Orthopaedic surgery 2021-08, Vol.13 (6), p.1781-1786 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective
To analyze the learning curve experience of hip arthroscopy based on patient demographics, surgical time, portal setup time, and postoperative complications and to find the key point in the learning curve.
Methods
From May 2016 to February 2019, a prospective study on the learning curve experience of hip arthroscopy was performed in our hospital. We evaluated the first 50 consecutive hip arthroscopy procedures performed by a single surgeon. There were nine females and 41 males with a mean age of 30.8 years. We divide the patients into early group and late group according to the date of their operation, with each group including 25 patients. Data on patient demographics, types of procedure, surgical time, portal setup time, and postoperative complications were collected. Functional scores were assessed with the modified Harris Hip Score (mHHS).
Results
Patients were followed up for 16.4 months on average (range, 13–27 months). The early group of patients had a mean age of 35.2 years and the late group a mean age of 26.5 years. The most common procedures performed for the early group were debridement (17 patients, 68%), and in the late group, most patients underwent labral repair (18 patients, 72%). Mean total surgical time was 168 min for the early group and 143 min for the late group, and there was no statistically significant difference between two groups. The portal setup time in the early group and late group was 40.2 ± 12.4 min and 18.5 ± 6.2 min, respectively (P |
---|---|