Bioresorbable vascular scaffolds versus conventional drug-eluting stents across time: a meta-analysis of randomised controlled trials

BackgroundBioresorbable vascular scaffolds (BVS) were designed to reduce the rate of late adverse events observed in conventional drug-eluting stents (DES) by dissolving once they have restored lasting patency.ObjectivesCompare the safety and efficacy of BVS versus DES in patients receiving percutan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Open heart 2022-10, Vol.9 (2), p.e002107
Hauptverfasser: Jackson-Smith, Elliot, Zioupos, Stephanie, Banerjee, Prithwish
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BackgroundBioresorbable vascular scaffolds (BVS) were designed to reduce the rate of late adverse events observed in conventional drug-eluting stents (DES) by dissolving once they have restored lasting patency.ObjectivesCompare the safety and efficacy of BVS versus DES in patients receiving percutaneous coronary intervention for coronary artery disease across a complete range of randomised controlled trial (RCT) follow-up intervals.MethodsA systematic review and meta-analysis was performed using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. MEDLINE, EMBASE and Web of Science were searched from inception through 5 January 2022 for RCTs comparing the clinical outcomes of BVS versus DES. The primary safety outcome was stent/scaffold thrombosis (ST), and the primary efficacy outcome was target lesion failure (TLF: composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR)). Secondary outcomes were patient-oriented composite endpoint (combining all-death, all-MI and all-revascularisation), its individual components and those of TLF. Studies were appraised using Cochrane’s Risk of Bias tool and meta-analysis was performed using RevMan V.5.4.Results11 919 patients were randomised to receive either BVS (n=6438) or DES (n=5481) across 17 trials (differing follow-up intervals from 3 months to 5 years). BVS demonstrated increased risk of ST across all timepoints (peaking at 2 years with risk ratio (RR): 3.47; 95% CI 1.80 to 6.70; p=0.0002). Similarly, they showed increased risk of TLF (peaking at 3 years, RR: 1.35; 95% CI 1.07 to 1.70; p=0.01) resulting from high rates of TVMI and ID-TLR. Though improvements were observed after device dissolution (5-year follow-up), these were non-significant. All other outcomes were statistically equivalent. Applicability to all BVS is limited by 91% of the BVS group receiving Abbott’s Absorb.ConclusionThis meta-analysis demonstrates that current BVS are inferior to contemporary DES throughout the first 5 years at minimum.
ISSN:2053-3624
2398-595X
2053-3624
DOI:10.1136/openhrt-2022-002107