Evaluation of electrocardiographic P wave parameters in predicting long-term atrial fibrillation in patients with acute ischemic stroke
Abstract Background Electrocardiographic parameters, such as P wave peak time (PWPT), P wave duration (PWD), and P wave amplitude in lead DI, have been utilized to assess left atrial anomalies linked to the development of atrial fibrillation (AF) in different cohort settings. Objective To compare...
Gespeichert in:
Veröffentlicht in: | Arquivos de neuro-psiquiatria 2022-09, Vol.80 (9), p.877-884 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Background
Electrocardiographic parameters, such as P wave peak time (PWPT), P wave duration (PWD), and P wave amplitude in lead DI, have been utilized to assess left atrial anomalies linked to the development of atrial fibrillation (AF) in different cohort settings.
Objective
To compare electrocardiographic parameters, such as P waves, in predicting long-term AF risk in acute ischemic stroke cases.
Methods
The data of 231 consecutive acute ischemic stroke cases were retrospectively collected. Two independent cardiologists interpreted the electrocardiography recordings for PWPT, PWD, and P wave amplitude in lead DI. The median follow-up study period was 16 (interquartile range [IQR]: 11–24) months.
Results
In total, AF was detected in 43 (18.6%) cases. All studied P wave parameters were found to be statistically significant in cases with AF. Based on multivariable logistic regression analysis, dementia, left atrium volume index, PWD (razão de chances [RC]: 1.11; 95% confidence interval [CI]: 1.058–1.184;
p
= 0.003), PWPT in lead DII (RC: 1.030; 95%CI: 1.010–1.050;
p
= 0.003), and advanced interatrial block morphology were independent predictors of long-term AF. P wave duration had the highest area under the curve value, sensitivity, and specificity for long-term AF in such cases compared with the other P wave parameters.
Conclusions
Our head-to-head comparison of well-known P wave parameters demonstrated that PWD might be the most useful P wave parameter for long-term AF in acute ischemic stroke cases. |
---|---|
ISSN: | 0004-282X 1678-4227 1678-4227 |