Analysis of Cooling Characteristics of Permanent Magnet Synchronous Motor with Different Water Jacket Design Using Electromagnetic–Thermal Fluid Coupled Analysis and Design of Experiment

Electrical losses are converted into thermal energy in motors, which heats each component. It is a significant factor in decreasing motor mechanical performance. In this paper, the motor cooling characteristics were analyzed according to the design factors of the water jacket to investigate the cool...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Machines (Basel) 2023-09, Vol.11 (9), p.903
Hauptverfasser: Jeon, Kyunghun, Park, Myungwoo, Park, Jongjin, Choi, Hongjun, Lee, Ki-Deok, Lee, Jeong-Jong, Kim, Chang-Wan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Electrical losses are converted into thermal energy in motors, which heats each component. It is a significant factor in decreasing motor mechanical performance. In this paper, the motor cooling characteristics were analyzed according to the design factors of the water jacket to investigate the cooling performance of a permanent magnet synchronous motor (PMSM). First, the electrical losses generated in PMSM were calculated using electromagnetic finite element (FE) analysis. Secondly, a 3D electromagnetic–thermal fluid coupled FE analysis was performed to analyze the temperature distribution inside the motor by applying electrical loss as the heat source. Finally, the motor cooling performance according to the design factors of the water jacket was statistically analyzed using the design of experiment (DOE) method. It was found that the mass flow rate of 0.02547 kg/s and six passes of the water jacket with one inlet and two outlets could be considered the optimum conditions in terms of the maximum motor temperature.
ISSN:2075-1702
2075-1702
DOI:10.3390/machines11090903