Assessing the performance of LumiraDx™ SARS-CoV-2 Ag test in detecting Omicron lineages: 2022–2023 study
The introduction of rapid antigen tests revolutionized the approach to SARS-CoV-2 diagnosis, offering prompt and accurate results with high sensitivity and specificity. Although it is more cost- and time-saving than the gold standard, real-time polymerase chain reaction (RT-PCR), the efficacy in gen...
Gespeichert in:
Veröffentlicht in: | Heliyon 2024-06, Vol.10 (12), p.e33229, Article e33229 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The introduction of rapid antigen tests revolutionized the approach to SARS-CoV-2 diagnosis, offering prompt and accurate results with high sensitivity and specificity. Although it is more cost- and time-saving than the gold standard, real-time polymerase chain reaction (RT-PCR), the efficacy in general population screening in both hospital- and community-based settings remains unknown. Moreover, rapid antigen testing is limited by qualitative results. This study aims to evaluate the diagnostic reliability of the LumiraDx™ rapid antigen test during the Omicron era and to investigate its quantitative (analogue-to-digital converter (ADC)) results in comparison with RT-PCR Ct values.
This prospective study included all adult patients with mild-to-moderate SARS-CoV-2 symptoms who were not hospitalised and did not require oxygen supplementation, consented to participate, and attended the Infectious and Tropical Diseases Unit of Padua University Hospital from July 14th, 2022 to January 3rd, 2023. The patients underwent two different tests simultaneously: a nasal LumiraDx™ swab and a real-time RT-PCR assay performed on a nasopharyngeal swab. Sampling was repeated several times for a subset of subjects.
We enrolled 266 consecutive participants and collected 601 pairs of LumiraDx™ and RT-PCR samples. The most prevalent variant was BA.4/BA.5 Omicron (60.2 %). The sensitivity and specificity of LumiraDx™ test when compared to real-time RT-PCR results as the reference standard were 93.1 % and 79.75 %, respectively. No significant differences in diagnostic reliability were found based on the available characteristics, age, sex, symptom status, or COVID-19 variant, except for the days from symptom onset. According to the multilevel logistic regression analysis, the only independent variable significantly associated with test concordance was the Ct value (adjusted odds ratio (OR) = 0.56, p |
---|---|