Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns

This study aimed to evaluate and compare the marginal gap using two different methods and the internal fit of 3D printed and zirconia crowns. 3Y-TZP zirconia crowns (n = 20) were manufactured using subtractive milling (group M) and 3D printed (group P). The marginal gap was measured at 60 points usi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC oral health 2023-07, Vol.23 (1), p.448-448, Article 448
Hauptverfasser: Refaie, Ashraf, Fouda, Ahmed, Bourauel, Christoph, Singer, Lamia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to evaluate and compare the marginal gap using two different methods and the internal fit of 3D printed and zirconia crowns. 3Y-TZP zirconia crowns (n = 20) were manufactured using subtractive milling (group M) and 3D printed (group P). The marginal gap was measured at 60 points using vertical marginal gap technique (VMGT). On the other hand, the silicone replica technique (SRT) was used to evaluate the internal fit and was divided into 4 groups: marginal gap, cervical gap, axial gap, and occlusal gap where the thickness of light impression was measured at 16 references. The numerical data was tested for normality using Shapiro-Wilk's test. They were found to be normally distributed and were analyzed using an independent t-test. Using VMGT, group P had significantly higher mean marginal gap values of 80 ± 30 µm compared to group M = 60 ± 20 µm (p 
ISSN:1472-6831
1472-6831
DOI:10.1186/s12903-023-03184-8